Sale!

Vivotek HLG-80H-24 80W Single Output Switching Power Supply, 24V, 90~3

HLG-80H-24: 80W Single Output Switching Power Supply, 24V, 90~305VAC In ,24VDC/80W Out ,IP67, – 40 ? ~ 70 ?, 3 Year Warranty, Supports: SD9361-EH/SD9361-EHL/SD9362-EH/SD9362-EHL

$75.00

Out of stock

SKU: VIVOTEK:HLG-80H-24 Categories: , ,

HLG-80H-24: 80W Single Output Switching Power Supply, 24V, 90~305VAC In ,24VDC/80W Out ,IP67, – 40 ℃ ~ 70 ℃, 3 Year Warranty, Supports: SD9361-EH/SD9361-EHL/SD9362-EH/SD9362-EHL

Technical Specifications

Model: HLG-80H-24

OUTPUT

DC VOLTAGE:  24V
CONSTANT CURRENT REGION: 14.4 ~ 24V
RATED CURRENT: 3.4A
RATED POWER: 81.6W
RIPPLE & NOISE (max.): 150mVp-p
VOLTAGE ADJ. RANGE: 22 ~ 27V
CURRENT ADJ. RANGE:
Can be adjusted by internal potentiometer A type only
2.04 ~ 3.4A
VOLTAGE TOLERANCE: ±1.0%
LINE REGULATION: ±0.5%
LOAD REGULATION: ±0.5%
SETUP, RISE TIME: 1200ms,80ms/115VAC 500ms,80ms/230VAC at full load; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.): 16ms at full load 230VAC /115VAC

INPUT

VOLTAGE RANGE: 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE: 47 ~ 63Hz
POWER FACTOR (Typ.): PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION: THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ.): 90.5%
AC CURRENT (Typ.): 0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
INRUSH CURRENT (Typ.): COLD START 70A(twidth=485μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER: 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT: <0.75mA / 277VAC

PROTECTION

OVER CURRENT: 95 ~ 108%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE:
28 ~ 35V
Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.: -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY: 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/℃ (0 ~ 60℃)
VIBRATION: 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS:
UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H-□BL, EN61347-1,
EN61347-2-13 independent, optional models for J61347-1, J61347-2-13, IP65 or IP67 approved; Design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE: I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3
EMC IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A

OTHERS

MTBF: 357.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION: 195.6*61.5*38.8mm (L*W*H)
PACKING: 0.84Kg; 16pcs/14.4Kg/0.54CUFT