Sale!

Flir A310-PT-15-N-S FLIR A310 PT 15° NTSC (9 HZ)

Flir

FLIR A310 PT 15° NTSC (9 HZ)

model:A310-PT-15-N-S

 

$26,193.27

MPN: A310-PT-15-N-S SKU: FLIR:A310-PT-15-N-S Categories: , , ,

A310-PT-15-N-S:FLIR A310 PT 15° NTSC (9 HZ)

A310-PT-15-N-S

Security professionals around the world have been using FLIR thermal cameras for perimeter and critical asset security for years. Facility Operations and Safety personnel have been using FLIR cameras to gather non-contact temperature measurements and condition monitoring data for decades. A310F and A310PT cameras are the first in the world to combine thermal and visible light video security imaging with automated safety monitoring based on the detection of temperature measurement thresholds.

 

  • Perimeter security Dual thermal and visible payloads, with analytics, provide best-in-class intrustion detection.
  • Equipment monitoring By measuring slight changes in surface temperature, the FLIR A310PT can detect hotspots or overheating equipment.
  • Wide-area surveillance for fire detection If the camera detects temperatures that exceed pre-set levels, it generates an alarm, alerting security personnel of potential threats.
Specifications
Communication & Data Storage
Ethernet
Control, result and image
Ethernet Communication
TBA
Ethernet Connector Type
RJ-45
Ethernet Protocols
Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
100 Mbps
Ethernet Video Streaming
Two independent channels for each camera – MPEG-4, H.264, or M-JPEG
Video Out
Composite video output, PAL /NTSC compatible
Environmental & Certifications
Bump
5 g, 11 ms (IEC 60068-2-27)
Elevation Range
El velocity ± 45°, 0.1 to 30°/sec. max
EMC
EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission) , FCC 47 CFR Part 15 Class B (Emission)
Encapsulation
IP 66 (IEC 60529)
Humidity (Operating and Storage)
IEC 60068-2-30/24 h 95% relative humidity +25° C to +40°C (+77°F to +104°F)
Operating Temperature Range
–25°C to +50°C (-13°F to +122°F)
Storage Temperature Range
–40°C to +70°C (–40°F to +158°F)
Vibration
2 g (IEC 60068-2-6)
General
Automatic Heater
Clears window from ice. Switched on at +4°C (39°F). Switched off at +15°C (59°F).
Housing material
Aluminum
List of Contents
Cardboard box, Pan & tilt with infrared camera including lens, and visual camera, FLIR Sensors Manager download card, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Packaging Size
671 x 564 x 464 mm (26.4 x 22.2 x 18.3 in.)
Size (L x W x H)
460 × 467 × 326 mm (18.1 × 18.4 × 12.8 in.)
Weight
17.8 kg (39.3 lb.)
Imaging & Optical
Azimuth Range
Az velocity 360° continuous, 0.1 to 60°/sec max
Color Palettes
Color palettes (BW, BW inv, Iron, Rain)
Detector Pitch
25 µm
Detector Time Constant
Typical 12 ms
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
Effective Pixels
380.0
Electronic Zoom
12× continuous, digital, interpolating
Field of view – visual
57.8° (H) to 1.7° (H)
Field of view (FOV)
25° × 18.8°
f-number
1.3
f-number – visual
1.6 to 4.5
Focal Length
18 mm (0.7 in.)
focal length – visual
3.4 mm (wide) to 122.4 mm (tele)
Focal Plane Array (FPA)
1/4” Exview HAD CCD
Focus
Automatic or manual (built in motor)
focus – visual
Automatic or manual (built in motor)
Image Frequency
9Hz
IR Resolution
320 × 240 pixels
Lens Identification
Automatic
Minimum Focus Distance
0.4 m (1.31 ft.)
Optical Zoom
36× continuous
Spatial resolution (IFOV)
1.36 mrad
Spectral Range
7.5–13 µm
Thermal Sensitivity/NETD
< 0.05°C @ +30°C (+86°F) / 50 mK
Video Standard
CVBS (ITU-R-BT.470 PAL), CVBS (SMPTE 170M NTSC)
Zoom
1–8× continuous, digital, interpolating zooming on images
Measurement & Analysis
Accuracy
±4°C (±7.2°F) or ±4% of reading
Alarm Functions
6 automatic alarms on any selected measurement function, camera temperature
Area
10 boxes with max./min./average/position
Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Emissivity Correction
Variable from 0.01 to 1.0
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Isotherm
1 with above/below/interval
Measurement Corrections
Global and individual object parameters
Object Temperature Range
–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Programmable Presets
128.0
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
Set-up Commands
Date/time, Temperature°C/°F
Spot Meter
10.0
Power
Power
24 VAC (21-30 VAC; 24 VAC: 215 VA max. with heater) or 24 VDC (21-30 VDC; 24 VDC: 195 W max. with heater).