A310-PT-15-N-S:FLIR A310 PT 15° NTSC (9 HZ)
A310-PT-15-N-S
Security professionals around the world have been using FLIR thermal cameras for perimeter and critical asset security for years. Facility Operations and Safety personnel have been using FLIR cameras to gather non-contact temperature measurements and condition monitoring data for decades. A310F and A310PT cameras are the first in the world to combine thermal and visible light video security imaging with automated safety monitoring based on the detection of temperature measurement thresholds.
- Perimeter security Dual thermal and visible payloads, with analytics, provide best-in-class intrustion detection.
- Equipment monitoring By measuring slight changes in surface temperature, the FLIR A310PT can detect hotspots or overheating equipment.
- Wide-area surveillance for fire detection If the camera detects temperatures that exceed pre-set levels, it generates an alarm, alerting security personnel of potential threats.
Specifications
Communication & Data Storage
- Ethernet
- Control, result and image
- Ethernet Communication
- TBA
- Ethernet Connector Type
- RJ-45
- Ethernet Protocols
- Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
- Ethernet Standard
- IEEE 802.3
- Ethernet Type
- 100 Mbps
- Ethernet Video Streaming
- Two independent channels for each camera – MPEG-4, H.264, or M-JPEG
- Video Out
- Composite video output, PAL /NTSC compatible
Environmental & Certifications
- Bump
- 5 g, 11 ms (IEC 60068-2-27)
- Elevation Range
- El velocity ± 45°, 0.1 to 30°/sec. max
- EMC
- EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission) , FCC 47 CFR Part 15 Class B (Emission)
- Encapsulation
- IP 66 (IEC 60529)
- Humidity (Operating and Storage)
- IEC 60068-2-30/24 h 95% relative humidity +25° C to +40°C (+77°F to +104°F)
- Operating Temperature Range
- –25°C to +50°C (-13°F to +122°F)
- Storage Temperature Range
- –40°C to +70°C (–40°F to +158°F)
- Vibration
- 2 g (IEC 60068-2-6)
General
- Automatic Heater
- Clears window from ice. Switched on at +4°C (39°F). Switched off at +15°C (59°F).
- Housing material
- Aluminum
- List of Contents
- Cardboard box, Pan & tilt with infrared camera including lens, and visual camera, FLIR Sensors Manager download card, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
- Packaging Size
- 671 x 564 x 464 mm (26.4 x 22.2 x 18.3 in.)
- Size (L x W x H)
- 460 × 467 × 326 mm (18.1 × 18.4 × 12.8 in.)
- Weight
- 17.8 kg (39.3 lb.)
Imaging & Optical
- Azimuth Range
- Az velocity 360° continuous, 0.1 to 60°/sec max
- Color Palettes
- Color palettes (BW, BW inv, Iron, Rain)
- Detector Pitch
- 25 µm
- Detector Time Constant
- Typical 12 ms
- Detector Type
- Focal Plane Array (FPA), uncooled microbolometer
- Effective Pixels
- 380.0
- Electronic Zoom
- 12× continuous, digital, interpolating
- Field of view – visual
- 57.8° (H) to 1.7° (H)
- Field of view (FOV)
- 25° × 18.8°
- f-number
- 1.3
- f-number – visual
- 1.6 to 4.5
- Focal Length
- 18 mm (0.7 in.)
- focal length – visual
- 3.4 mm (wide) to 122.4 mm (tele)
- Focal Plane Array (FPA)
- 1/4” Exview HAD CCD
- Focus
- Automatic or manual (built in motor)
- focus – visual
- Automatic or manual (built in motor)
- Image Frequency
- 9Hz
- IR Resolution
- 320 × 240 pixels
- Lens Identification
- Automatic
- Minimum Focus Distance
- 0.4 m (1.31 ft.)
- Optical Zoom
- 36× continuous
- Spatial resolution (IFOV)
- 1.36 mrad
- Spectral Range
- 7.5–13 µm
- Thermal Sensitivity/NETD
- < 0.05°C @ +30°C (+86°F) / 50 mK
- Video Standard
- CVBS (ITU-R-BT.470 PAL), CVBS (SMPTE 170M NTSC)
- Zoom
- 1–8× continuous, digital, interpolating zooming on images
Measurement & Analysis
- Accuracy
- ±4°C (±7.2°F) or ±4% of reading
- Alarm Functions
- 6 automatic alarms on any selected measurement function, camera temperature
- Area
- 10 boxes with max./min./average/position
- Atmospheric transmission correction
- Automatic, based on inputs for distance, atmospheric temperature and relative humidity
- Emissivity Correction
- Variable from 0.01 to 1.0
- External Optics & Windows Correction
- Automatic, based on input of optics/window transmission and temperature
- Isotherm
- 1 with above/below/interval
- Measurement Corrections
- Global and individual object parameters
- Object Temperature Range
- –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
- Optics Transmission Correction
- Automatic, based on signals from internal sensors
- Programmable Presets
- 128.0
- Reflected apparent temperature correction
- Automatic, based on input of reflected temperature
- Set-up Commands
- Date/time, Temperature°C/°F
- Spot Meter
- 10.0
Power
- Power
- 24 VAC (21-30 VAC; 24 VAC: 215 VA max. with heater) or 24 VDC (21-30 VDC; 24 VDC: 195 W max. with heater).